Power-over-Ethernet: Difference between revisions

From Bay Area Mesh
Jump to navigation Jump to search
(draft !)
(draft)
Line 1: Line 1:
 
[[wikipedia:Power_over_Ethernet|This Wiki dosn't accurately describe the way Ubiquity deploys PoE]] Please expect to encounter [https://planetechusa.com/power-over-ethernet-poe-demystifying-mode-a-and-mode-b/ mode B] on the T568B wiring standard for data over an 8wire / 4pair [[wikipedia:Category_5_cable|Cat 5e utp cable.]]
 
[[wikipedia:Power_over_Ethernet|This Wiki dosn't accurately describe the way Ubiquity deploys PoE]] Please expect to encounter [https://planetechusa.com/power-over-ethernet-poe-demystifying-mode-a-and-mode-b/ mode B] on the T568B wiring standard for data over an 8wire / 4pair [[wikipedia:Category_5_cable|Cat 5e utp cable.]]
   
All of the AirMax and GL.iNet class devices have 100Mbps Ethernet ports. They receive power via that Ethernet port as well. 24V DC is sent over the cat 5e line. The DC voltage is injected on "spare pairs" unused by 100Mbps Ethernet. A fixed DC voltage is provided (positive voltage to pins 4- 5) and (negative voltage to pins 7-8. You might ask...Q: How do devices running with 1000Mbps Ethernet ports receive power? The [https://en.mag-tek.com.tw/products_detail/180.htm G24102HKG chip] is how! [https://datasheetspdf.com/pdf-file/921604/MAGTEK/G24102MK/1 Data sheet] [https://www.mouser.com/datasheet/2/143/EL817-G-26528.pdf 26528.pdf.]
+
All of the AirMax and GL.iNet class devices have 100Mbps Ethernet ports. They receive power via that Ethernet port as well. 24V DC is sent over the cat 5e line. The DC voltage is injected on "spare pairs" unused by 100Mbps Ethernet. A fixed DC voltage is provided (positive voltage to pins 4- 5) and (negative voltage to pins 7-8. You might ask...Q: How do devices running with 1000Mbps Ethernet ports receive power? The [https://en.mag-tek.com.tw/products_detail/180.htm G24102HKG chip] is how! [https://datasheetspdf.com/pdf-file/921604/MAGTEK/G24102MK/1 Data sheet] [https://www.mouser.com/datasheet/2/143/EL817-G-26528.pdf 26528.pdf.]
  +
[[File:CAT6 twisted pair.jpg|left|thumb|300x300px]]
  +
  +
  +
  +
  +
  +
  +
  +
   
   
 
==== GB-B240-100. ====
 
==== GB-B240-100. ====
[[File:GB-B240-100side CASE.jpg|border|frameless|300x300px]][[File:GB-B240-100side A.jpg|border|frameless]]
+
[[File:GB-B240-100side_CASE.jpg|none|thumb|300x300px]]
  +
[[File:GB-B240-100side A.jpg|border|frameless]]
 
[[File:GB-B240-100 pcb back.jpg|border|frameless]]
 
[[File:GB-B240-100 pcb back.jpg|border|frameless]]
   
Line 18: Line 28:
 
[[File:GB-H240-100-4 case.jpg|none|thumb|300x300px]]
 
[[File:GB-H240-100-4 case.jpg|none|thumb|300x300px]]
 
[[File:GB-H240-100-4 pcb top.jpg|frameless]][[File:GB-H240-100-4 pcb under.jpg|frameless|533x533px]]
 
[[File:GB-H240-100-4 pcb top.jpg|frameless]][[File:GB-H240-100-4 pcb under.jpg|frameless|533x533px]]
  +
 
This is a gray 1 amp 1000Mbps injector. Power is sent over all 4 pairs with data. The injector are found in the box of AirFiberX and AC-Gen2 devices. Don't forget the white model, its a Passive 1000Mbps PoE injector as well.
 
This is a gray 1 amp 1000Mbps injector. Power is sent over all 4 pairs with data. The injector are found in the box of AirFiberX and AC-Gen2 devices. Don't forget the white model, its a Passive 1000Mbps PoE injector as well.
  +
   
   

Revision as of 00:28, 7 September 2022

This Wiki dosn't accurately describe the way Ubiquity deploys PoE Please expect to encounter mode B on the T568B wiring standard for data over an 8wire / 4pair Cat 5e utp cable.

All of the AirMax and GL.iNet class devices have 100Mbps Ethernet ports. They receive power via that Ethernet port as well. 24V DC is sent over the cat 5e line. The DC voltage is injected on "spare pairs" unused by 100Mbps Ethernet. A fixed DC voltage is provided (positive voltage to pins 4- 5) and (negative voltage to pins 7-8. You might ask...Q: How do devices running with 1000Mbps Ethernet ports receive power? The G24102HKG chip is how! Data sheet 26528.pdf.

CAT6 twisted pair.jpg






GB-B240-100.

GB-B240-100side CASE.jpg

GB-B240-100side A.jpg GB-B240-100 pcb back.jpg

This is a black 1 amp 100Mbps injector. Its not possible to obtain 1000Mbps port speed with a GB-B240-100, pins 4- 5 and pins 7-8 have been observe to no be connected on the LAN side of the injector.

GB-B240-100.

(pic)

black 1/2 amp

GB-H240-100-4

GB-H240-100-4 case.jpg

GB-H240-100-4 pcb top.jpgGB-H240-100-4 pcb under.jpg

This is a gray 1 amp 1000Mbps injector. Power is sent over all 4 pairs with data. The injector are found in the box of AirFiberX and AC-Gen2 devices. Don't forget the white model, its a Passive 1000Mbps PoE injector as well.



Power is sent through the passive power pairs. Data on all 4pairs are used when operating

Caution! connecting any 48v PoE standard to a passive device will damage a passive device!

This Wiki dosn't accurately describe the Ubiquity PoE

Great article that parallel my interest with POE.

Gigabit PoE Injector

Tycon Power Systems POE-INJ-1000-WTx Gigabit PoE Injector/Splitter 4 Pair

?24V, 2-Pair Passive PoE

The nanoswitch accept 4pair passive poe and 2pair passive poe for power. Then we have 3 types of devices being powered... one type runs 2 pair passive 24v poe and runs at 1Gb port speed. Two a device that runs on 4 pair passive 24v poe runs at 1Gb, and the most common 2 pair passive 24v poe running at 100Mb.  1Gb devices have power isolation on all 4pairs but may only pull from 2 pairs! Ive found that for an AirFiber3x device to reach full tx power levels while sharing a Nanoswitch with another 2 pair device the Nanoswitch needs to be feed 4pair passive 24v power.